Water softener size calculator
Enter your water's hardness and your household. You get the grains your softener has to remove each day, the rated capacity to buy, and how often it will regenerate. Every step of the arithmetic is shown under the result.
The formula
1. Hardness in grains per gallon. Utility reports give mg/L (the same number as ppm). Divide by 17.1 to get gpg.
2. Add iron, if you have it. Dissolved iron takes up exchange sites on the resin just like calcium and magnesium. The Water Quality Association adds the iron reading in ppm times a factor, typically 3 and sometimes 2, 4 or 5, and calls the total compensated hardness. Many dealers use 4, and that is our default. You can change it under “More options”.
3. Grains per day = compensated hardness × people × gallons per person per day. This is Penn State Extension's method: their example of 4 people using 75 gallons each at 10 gpg comes to 3,000 grains a day.
4. Rated capacity needed = grains per day × days between regenerations ÷ the share of the rating you will actually get. Round up to the next common size: 24,000, 32,000, 40,000, 48,000, 64,000, 80,000, 96,000 or 110,000 grains.
Why we divide by ⅔
A softener's advertised capacity is measured at its highest salt dose. Resin makers rate one cubic foot at about 30,000 grains when it is regenerated with 15 lb of salt, but only about 20,000 grains with 6 lb. The 6 lb setting removes far more hardness per pound of salt, so it is the one worth running. It delivers two thirds of the headline figure.
So a family that needs 21,000 grains between regenerations should buy a unit rated for about 31,500 grains, a 32,000, and run it at the efficient setting, rather than buy a 24,000 and run it at full salt for life. If you would rather run maximum salt, switch the setting under “More options” and the ⅔ factor drops out.
How many days between regenerations?
We default to about a week, in line with Penn State's example of a 20,000-grain unit regenerating every 6 to 7 days. Nelsen's dealer sizing notes use 3 to 5 days instead, which gives a smaller tank that regenerates, and uses rinse water, more often. Pick what suits you under “More options”. Choose a metered (demand-initiated) valve either way: it regenerates by gallons used, not by the calendar.
Worked examples you can check
- Penn State's example. 4 people, 75 gallons, 10 gpg: 3,000 grains a day. Put 20,000 in “Already have a softener?” with the maximum salt setting and you get 6.7 days, their “about 6–7 day regeneration”.
- WQA's iron example. 10 gpg plus 3 ppm iron at a factor of 3 is 19 gpg. At 4 people and 70 gallons that is 5,320 grains a day.
- Lincoln, Nebraska. The top of Lincoln's published range is 236 mg/L (13.8 gpg). For 4 people at 75 gallons: 4,140 grains a day, 28,982 for a week, ÷ ⅔ = 43,474, so a 48,000-grain unit that regenerates about every 7 days. Lincoln's page.
Don't know your hardness?
Search for your city at the top of the page. Every figure we list comes from the utility's own report. On a city page, the calculator is already filled in with that city's number.
On a private well, test the water. A lab test also reports iron. Above pH 6.5, iron oxidizes easily and fouls resin, so WQA suggests keeping a softener's iron load under about 3 ppm, and many units are rated for 2 ppm. Above that, plan an iron filter ahead of the softener.
Want the running cost? The salt calculator takes the same inputs and works out pounds, bags and dollars a year.
Sources
Each constant in this calculator comes from one of these documents. We checked them on November 19, 2026.
- Penn State Extension, “Water Softening (Robillard, Sharpe and Swistock; updated September 8, 2025)”. What we use: 1 gpg ≈ 17 mg/L; the five-step gpg hardness scale (Table 1); the sizing example 75 gal × 10 gpg × 4 people = 3,000 grains a day, so a 20,000-grain unit regenerates about every 6–7 days; below 7 gpg scale and soap film are usually minor; oxidized (red) iron fouls resin.
- Water Quality Association (WQA) Knowledge Base, “Calculating Ion Exchange Water Softener Capacity”. What we use: Compensated hardness: add iron (ppm) × a factor, “typically 3, but may be 2, 4, or 5”; 70 gal per person per day of indoor use as a starting point; above pH 6.5 keep iron treated by a softener under about 3 ppm. Some WQA pages ask for a member sign-in.
- Nelsen Corporation (water treatment equipment distributor), “Softener Sizing Calculator: method notes”. What we use: Compensated hardness = gpg + 4 × iron ppm; 75 gal per person per day; most softeners are rated for up to 2 ppm of ferrous iron.
- Marlo Inc. (softener manufacturer), “MGT Series Water Softeners brochure, capacity footnote”. What we use: Maximum capacity 30,000 grains per ft³ of resin regenerated with 15 lb of salt; minimum 20,000 grains per ft³ with 6 lb. That ratio is our ⅔ “salt-efficient” factor, and it gives 2,000 and about 3,333 grains removed per lb of salt.
- NSF, “NSF/ANSI 44 Cation Exchange Water Softeners: certified product listings, efficiency-rating note”. What we use: An efficiency-rated [ER] softener removes at least 3,350 grains of hardness per lb of salt and uses 5 gallons or less of regeneration water per 1,000 grains removed.
- U.S. Department of Energy, Building America Solution Center (PNNL), “Water Softeners”. What we use: The same NSF/ANSI 44 efficiency criteria, and that only demand-initiated (metered or sensor) softeners can be efficiency rated; time-clock units regenerate on a schedule whether or not the resin is spent.
- U.S. EPA WaterSense, “Statistics and Facts”. What we use: Each American uses an average of 82 gallons of water a day at home (citing USGS water-use estimates for 2015).
- U.S. Geological Survey, Water Science School, “Hardness of Water”. What we use: The four bands in mg/L as CaCO₃: 0–60 soft, 61–120 moderately hard, 121–180 hard, over 180 very hard.
The calculator runs in your browser. Nothing you type is sent to us or stored. Found an error? Tell us and we'll correct it.
Other calculators
Softener salt and cost calculator
Pounds of salt, bags and dollars a year for your hardness and household, and how much an efficient setting saves.
Open →Hardness unit converter
mg/L, ppm, grains per gallon, German, French and English degrees and mmol/L, plus hardness from a calcium and magnesium lab result.
Open →Is my water hard?
Enter a number from a test strip or report and see where it falls on the USGS and Penn State scales, with cities that match.